How to Fix Common Issues with Hydrocyclones - Townley …
· To fix this, increase the density of solids feeding the hydrocyclone, or decrease the size of the apex. The apex will be the fastest wearing part of most units. When the apex wears out, the opening gets larger, therefore allowing more water to go out the underflow. To fix this, replace the apex with a new one.